{"id":810,"date":"2026-08-10T11:26:26","date_gmt":"2026-08-10T11:26:26","guid":{"rendered":"https:\/\/www.effegigroup.it\/news-effegi\/71-cold-cutting-reactor\/"},"modified":"2026-08-27T15:59:58","modified_gmt":"2026-08-27T15:59:58","slug":"71-cold-cutting-reactor","status":"publish","type":"page","link":"https:\/\/www.effegigroup.it\/en\/news-effegi\/71-cold-cutting-reactor\/","title":{"rendered":"Cold cutting of the reactor"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"810\" class=\"elementor elementor-810 elementor-325\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c0035 e-con-full e-flex e-con e-parent\" data-id=\"c0035\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c0034 e-con-boxed e-flex e-con e-parent\" data-id=\"c0034\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-c0033 e-con-full e-flex e-con e-child\" data-id=\"c0033\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-c0009 e-con e-atomic-element e-div-block-base \" data-id=\"c0009\" data-element_type=\"e-div-block\" data-e-type=\"e-div-block\" data-interaction-id=\"c0009\" data-e-type=\"e-div-block\" data-id=\"c0009\">\n    \t\t\t<h1 data-interaction-id=\"w0006\" class=\"g-titolo-pagina e-heading-base\" data-e-type=\"widget\" data-id=\"w0006\">News from Effegi<\/h1>\n\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" class=\"e-image-base g-immagine\" data-interaction-id=\"w0007\" data-e-type=\"widget\" data-id=\"w0007\" id=\"321\" src=\"https:\/\/www.effegigroup.it\/wp-content\/uploads\/2026\/08\/sezionamento-idrotagli.jpg\" width=\"800\" height=\"450\" srcset=\"https:\/\/www.effegigroup.it\/wp-content\/uploads\/2026\/08\/sezionamento-idrotagli.jpg 845w, https:\/\/www.effegigroup.it\/wp-content\/uploads\/2026\/08\/sezionamento-idrotagli-300x169.jpg 300w, https:\/\/www.effegigroup.it\/wp-content\/uploads\/2026\/08\/sezionamento-idrotagli-768x432.jpg 768w\" alt=\"\"\/>\t\t\t\t<div class=\"elementor-element elementor-element-w0008 testo-introduttivo elementor-widget elementor-widget-text-editor\" data-id=\"w0008\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<blockquote style=\"border-left:3px solid #4fcc81;margin:0 0 24px;padding:2px 0 2px 20px;font-style:italic\"><em><\/em> Created: 03 October 2017<\/blockquote>\t\t\t\t\t\t\t\t<\/div>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-c0011 e-con e-atomic-element e-div-block-base \" data-id=\"c0011\" data-element_type=\"e-div-block\" data-e-type=\"e-div-block\" data-interaction-id=\"c0011\" data-e-type=\"e-div-block\" data-id=\"c0011\">\n    \t\t\t<h1 data-interaction-id=\"w0010\" class=\"g-titolo-pagina e-heading-base\" data-e-type=\"widget\" data-id=\"w0010\">Cold cutting of the reactor<\/h1>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-c0015 e-con e-atomic-element e-div-block-base \" data-id=\"c0015\" data-element_type=\"e-div-block\" data-e-type=\"e-div-block\" data-interaction-id=\"c0015\" data-e-type=\"e-div-block\" data-id=\"c0015\">\n    \t\t\t<h2 data-interaction-id=\"w0012\" class=\"g-titolo-sezione e-heading-base\" data-e-type=\"widget\" data-id=\"w0012\">Objective of the work<\/h2>\n\t\t\t\t\t<p class=\"g-testo e-paragraph-base\" data-interaction-id=\"w0013\" data-e-type=\"widget\" data-id=\"w0013\">Cold cutting of the following components at an oil refinery using hydro jet cold-cutters:<\/p>\n\t\t\t\t<div class=\"elementor-element elementor-element-w0014 testo elementor-widget elementor-widget-text-editor\" data-id=\"w0014\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<ul><li>Riser (inside reactor)<\/li><li>Reactor overhead line<\/li><li>Reactor dome<\/li><li>Lines<\/li><li>Regenerator overhead line<\/li><li>Regenerator dome<\/li><li>Silencer<\/li><li>All hydro cutters to be of a suitable type to enable subsequent re-welding<\/li><li>All work to be carried out during an important turnaround.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-c0025 e-con e-atomic-element e-div-block-base \" data-id=\"c0025\" data-element_type=\"e-div-block\" data-e-type=\"e-div-block\" data-interaction-id=\"c0025\" data-e-type=\"e-div-block\" data-id=\"c0025\">\n    \t\t\t<h2 data-interaction-id=\"w0016\" class=\"g-titolo-sezione e-heading-base\" data-e-type=\"widget\" data-id=\"w0016\">Operating procedure<\/h2>\n\t\t\t\t\t<p class=\"g-testo e-paragraph-base\" data-interaction-id=\"w0017\" data-e-type=\"widget\" data-id=\"w0017\">Critical factors in the process were:<\/p>\n\t\t\t\t<div class=\"elementor-element elementor-element-w0018 testo elementor-widget elementor-widget-text-editor\" data-id=\"w0018\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<ul><li>cutting of considerably large objects, up to nearly 70m;<\/li><li>cutting of steel and refractory composites of considerable thickness (steel up to 20mm, refractories up to 150mm), some of RESCO type and others containing hex mesh;<\/li><li>cutting timescales to be rigorously observed owing to the restricted amount of time available and to the presence onsite of a large lifting crane.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<img decoding=\"async\" class=\"e-image-base g-immagine\" data-interaction-id=\"w0019\" data-e-type=\"widget\" data-id=\"w0019\" id=\"323\" src=\"https:\/\/www.effegigroup.it\/wp-content\/uploads\/2026\/08\/sezionamento-cupola-reattore.jpg\" width=\"800\" height=\"400\" srcset=\"https:\/\/www.effegigroup.it\/wp-content\/uploads\/2026\/08\/sezionamento-cupola-reattore.jpg 800w, https:\/\/www.effegigroup.it\/wp-content\/uploads\/2026\/08\/sezionamento-cupola-reattore-300x150.jpg 300w, https:\/\/www.effegigroup.it\/wp-content\/uploads\/2026\/08\/sezionamento-cupola-reattore-768x384.jpg 768w\" alt=\"\"\/>\t\t\t\t\t<p class=\"g-testo e-paragraph-base\" data-interaction-id=\"w0020\" data-e-type=\"widget\" data-id=\"w0020\">This work required simultaneous use of 3 hydro cutters of 2,000 and 2,500 bar class. Two of these operated in two daily turns of 11 hours each (22 hours per day for each machine), with a third machine on standby as a precaution on account of the strict timescales and high working pressures involved.<\/p>\n\t\t\t\t\t<p class=\"g-testo e-paragraph-base\" data-interaction-id=\"w0021\" data-e-type=\"widget\" data-id=\"w0021\">The following preparatory work was done first: transportation, unloading and positioning of the UHP machines, preparation and fixing of the flexible UHP and hydraulic lines, connection of lines and safety systems (containment grips), assembly of slide tracks and the hydraulic side shifter for the nozzle holders in line with the first two cuts to be made.<\/p>\n\t\t\t\t\t<p class=\"g-testo e-paragraph-base\" data-interaction-id=\"w0022\" data-e-type=\"widget\" data-id=\"w0022\">Both linear and circumferential side shifters were used for the cuts, guided by flexible tracks or double chain systems..<\/p>\n\t\t\t\t\t<p class=\"g-testo e-paragraph-base\" data-interaction-id=\"w0023\" data-e-type=\"widget\" data-id=\"w0023\">In addition to the personal protective equipment normally required for hydrodynamic cutting and for the type of installation worked on (an oil refinery), all personnel were equipped with the requisite safety systems for the type of work done and with ATEX certified radios for real-time coordination and communication.<\/p>\n\t\t\t\t\t<p class=\"g-testo e-paragraph-base\" data-interaction-id=\"w0024\" data-e-type=\"widget\" data-id=\"w0024\">All hydro cutting was done in full compliance with safety requirements and within the agreed timescales (finishing ahead of schedule) and the quality of the work was to the complete satisfaction of the customer.<\/p>\n\t\t\n<\/div>\n\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c0032 e-con e-atomic-element e-div-block-base g-colonna-laterale wdj-spalla \" data-id=\"c0032\" data-element_type=\"e-div-block\" data-e-type=\"e-div-block\" data-interaction-id=\"c0032\" data-e-type=\"e-div-block\" data-id=\"c0032\">\n    \t\t<div class=\"elementor-element elementor-element-w0026 elementor-widget elementor-widget-image\" data-id=\"w0026\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"\/en\/solutions-effegi\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"200\" height=\"200\" src=\"https:\/\/www.effegigroup.it\/wp-content\/uploads\/2026\/08\/soluzioni-side-button.png\" class=\"attachment-full size-full wp-image-213\" alt=\"\" srcset=\"https:\/\/www.effegigroup.it\/wp-content\/uploads\/2026\/08\/soluzioni-side-button.png 200w, https:\/\/www.effegigroup.it\/wp-content\/uploads\/2026\/08\/soluzioni-side-button-150x150.png 150w\" sizes=\"(max-width: 200px) 100vw, 200px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-w0027 elementor-align-center elementor-widget elementor-widget-button\" data-id=\"w0027\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/en\/solutions-effegi\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">OUR SOLUTIONS<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-w0028 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"w0028\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-w0029 elementor-widget elementor-widget-image\" data-id=\"w0029\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"\/en\/services-effegi\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"200\" height=\"200\" src=\"https:\/\/www.effegigroup.it\/wp-content\/uploads\/2026\/08\/servizi-side-button.png\" class=\"attachment-full size-full wp-image-215\" alt=\"\" srcset=\"https:\/\/www.effegigroup.it\/wp-content\/uploads\/2026\/08\/servizi-side-button.png 200w, https:\/\/www.effegigroup.it\/wp-content\/uploads\/2026\/08\/servizi-side-button-150x150.png 150w\" sizes=\"(max-width: 200px) 100vw, 200px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-w0030 elementor-align-center elementor-widget elementor-widget-button\" data-id=\"w0030\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/en\/services-effegi\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">OUR SERVICES<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\n<\/div>\n\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"","protected":false},"author":0,"featured_media":0,"parent":806,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_angie_page":false,"footnotes":""},"class_list":["post-810","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Cold cutting of the reactor - Manutenzioni industriali - Lavaggi ad alta pressione<\/title>\n<meta name=\"description\" content=\"Cold cutting of the following components at an oil refinery using hydro jet cold-cutters: Riser (inside reactor, Reactor overhead line, Reactor dome, Lines, Regenerator overhead line, Regenerator dome, Silencer, All hydro cutters to be of a suitable type to enable subsequent re-welding. All work to be carried out during an important turnaround\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.effegigroup.it\/en\/news-effegi\/71-cold-cutting-reactor\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Cold cutting of the reactor - Manutenzioni industriali - Lavaggi ad alta pressione\" \/>\n<meta property=\"og:description\" content=\"Cold cutting of the following components at an oil refinery using hydro jet cold-cutters: Riser (inside reactor, Reactor overhead line, Reactor dome, Lines, Regenerator overhead line, Regenerator dome, Silencer, All hydro cutters to be of a suitable type to enable subsequent re-welding. All work to be carried out during an important turnaround\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.effegigroup.it\/en\/news-effegi\/71-cold-cutting-reactor\/\" \/>\n<meta property=\"og:site_name\" content=\"Manutenzioni industriali - Lavaggi ad alta pressione\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-27T15:59:58+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.effegigroup.it\\\/en\\\/news-effegi\\\/71-cold-cutting-reactor\\\/\",\"url\":\"https:\\\/\\\/www.effegigroup.it\\\/en\\\/news-effegi\\\/71-cold-cutting-reactor\\\/\",\"name\":\"Cold cutting of the reactor - Manutenzioni industriali - Lavaggi ad alta pressione\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.effegigroup.it\\\/en\\\/#website\"},\"datePublished\":\"2026-08-10T11:26:26+00:00\",\"dateModified\":\"2026-08-27T15:59:58+00:00\",\"description\":\"Cold cutting of the following components at an oil refinery using hydro jet cold-cutters: Riser (inside reactor, Reactor overhead line, Reactor dome, Lines, Regenerator overhead line, Regenerator dome, Silencer, All hydro cutters to be of a suitable type to enable subsequent re-welding. All work to be carried out during an important turnaround\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.effegigroup.it\\\/en\\\/news-effegi\\\/71-cold-cutting-reactor\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.effegigroup.it\\\/en\\\/news-effegi\\\/71-cold-cutting-reactor\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.effegigroup.it\\\/en\\\/news-effegi\\\/71-cold-cutting-reactor\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.effegigroup.it\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"News from Effegi\",\"item\":\"https:\\\/\\\/www.effegigroup.it\\\/en\\\/news-effegi-group\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Cold cutting of the reactor\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.effegigroup.it\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.effegigroup.it\\\/en\\\/\",\"name\":\"Manutenzioni industriali - Lavaggi ad alta pressione\",\"description\":\"Manutenzioni, industriali, Lavaggi alta pressione\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.effegigroup.it\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.effegigroup.it\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.effegigroup.it\\\/en\\\/#organization\",\"name\":\"Manutenzioni industriali - Lavaggi ad alta pressione\",\"url\":\"https:\\\/\\\/www.effegigroup.it\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.effegigroup.it\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.effegigroup.it\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/Logo-Effegi-SpA.jpg\",\"contentUrl\":\"https:\\\/\\\/www.effegigroup.it\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/Logo-Effegi-SpA.jpg\",\"width\":299,\"height\":90,\"caption\":\"Manutenzioni industriali - Lavaggi ad alta pressione\"},\"image\":{\"@id\":\"https:\\\/\\\/www.effegigroup.it\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/effegi-srl\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Cold cutting of the reactor - Manutenzioni industriali - Lavaggi ad alta pressione","description":"Cold cutting of the following components at an oil refinery using hydro jet cold-cutters: Riser (inside reactor, Reactor overhead line, Reactor dome, Lines, Regenerator overhead line, Regenerator dome, Silencer, All hydro cutters to be of a suitable type to enable subsequent re-welding. All work to be carried out during an important turnaround","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.effegigroup.it\/en\/news-effegi\/71-cold-cutting-reactor\/","og_locale":"en_US","og_type":"article","og_title":"Cold cutting of the reactor - Manutenzioni industriali - Lavaggi ad alta pressione","og_description":"Cold cutting of the following components at an oil refinery using hydro jet cold-cutters: Riser (inside reactor, Reactor overhead line, Reactor dome, Lines, Regenerator overhead line, Regenerator dome, Silencer, All hydro cutters to be of a suitable type to enable subsequent re-welding. All work to be carried out during an important turnaround","og_url":"https:\/\/www.effegigroup.it\/en\/news-effegi\/71-cold-cutting-reactor\/","og_site_name":"Manutenzioni industriali - Lavaggi ad alta pressione","article_modified_time":"2026-08-27T15:59:58+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.effegigroup.it\/en\/news-effegi\/71-cold-cutting-reactor\/","url":"https:\/\/www.effegigroup.it\/en\/news-effegi\/71-cold-cutting-reactor\/","name":"Cold cutting of the reactor - Manutenzioni industriali - Lavaggi ad alta pressione","isPartOf":{"@id":"https:\/\/www.effegigroup.it\/en\/#website"},"datePublished":"2026-08-10T11:26:26+00:00","dateModified":"2026-08-27T15:59:58+00:00","description":"Cold cutting of the following components at an oil refinery using hydro jet cold-cutters: Riser (inside reactor, Reactor overhead line, Reactor dome, Lines, Regenerator overhead line, Regenerator dome, Silencer, All hydro cutters to be of a suitable type to enable subsequent re-welding. All work to be carried out during an important turnaround","breadcrumb":{"@id":"https:\/\/www.effegigroup.it\/en\/news-effegi\/71-cold-cutting-reactor\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.effegigroup.it\/en\/news-effegi\/71-cold-cutting-reactor\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.effegigroup.it\/en\/news-effegi\/71-cold-cutting-reactor\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.effegigroup.it\/en\/"},{"@type":"ListItem","position":2,"name":"News from Effegi","item":"https:\/\/www.effegigroup.it\/en\/news-effegi-group\/"},{"@type":"ListItem","position":3,"name":"Cold cutting of the reactor"}]},{"@type":"WebSite","@id":"https:\/\/www.effegigroup.it\/en\/#website","url":"https:\/\/www.effegigroup.it\/en\/","name":"Manutenzioni industriali - Lavaggi ad alta pressione","description":"Manutenzioni, industriali, Lavaggi alta pressione","publisher":{"@id":"https:\/\/www.effegigroup.it\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.effegigroup.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.effegigroup.it\/en\/#organization","name":"Manutenzioni industriali - Lavaggi ad alta pressione","url":"https:\/\/www.effegigroup.it\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.effegigroup.it\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.effegigroup.it\/wp-content\/uploads\/2026\/08\/Logo-Effegi-SpA.jpg","contentUrl":"https:\/\/www.effegigroup.it\/wp-content\/uploads\/2026\/08\/Logo-Effegi-SpA.jpg","width":299,"height":90,"caption":"Manutenzioni industriali - Lavaggi ad alta pressione"},"image":{"@id":"https:\/\/www.effegigroup.it\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/effegi-srl\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.effegigroup.it\/en\/wp-json\/wp\/v2\/pages\/810","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.effegigroup.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.effegigroup.it\/en\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/www.effegigroup.it\/en\/wp-json\/wp\/v2\/comments?post=810"}],"version-history":[{"count":1,"href":"https:\/\/www.effegigroup.it\/en\/wp-json\/wp\/v2\/pages\/810\/revisions"}],"predecessor-version":[{"id":811,"href":"https:\/\/www.effegigroup.it\/en\/wp-json\/wp\/v2\/pages\/810\/revisions\/811"}],"up":[{"embeddable":true,"href":"https:\/\/www.effegigroup.it\/en\/wp-json\/wp\/v2\/pages\/806"}],"wp:attachment":[{"href":"https:\/\/www.effegigroup.it\/en\/wp-json\/wp\/v2\/media?parent=810"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}